Security::LogProfile::set_application_format_user_defined¶
Introduced : BIG-IP_v11.3.0
Sets the storage format type to user-defined and sets the user string
in Application Security. This is relevant only for the remote storage
of type remote, since Splunk and ArcSight have their fixed format. For
consistent configuration, when changing the storage format type to
user-defined you must specify also the user-string. The available
storage format types are mentioned under the StorageFormat
enumeration. Please see set_application_user_string for more
information about every setting.
Prototype¶
set_application_format_user_defined(
in String [] profile_names,
in String [] [] applications,
in String [] [] texts
);
Parameters¶
Parameter | Type | Description |
profile_names | String [] | The names of the logging profiles. |
applications | String [] [] | The Application Security sub-profile names. |
texts | String [] [] | The user string in Application Security for each logging profile. |
Exceptions¶
Exception | Description |
Common::AccessDenied | Raised if the client credentials are not valid. |
Common::InvalidArgument | Raised if one of the arguments is invalid. |
Common::OperationFailed | Raised if an operation error occurs. |
See Also¶
iControl ::
Warning
The links to the sample code below are remnants of the old DevCentral wiki and will result in a 404 error. For best results, please copy the link text and search the codeshare directly on DevCentral.
Sample Code¶
The BIG-IP API Reference documentation contains community-contributed content. F5 does not monitor or control community code contributions. We make no guarantees or warranties regarding the available code, and it may contain errors, defects, bugs, inaccuracies, or security vulnerabilities. Your access to and use of any code available in the BIG-IP API reference guides is solely at your own risk.