ltm monitor diameterΒΆ

ltm monitor diameter(1) 				BIG-IP TMSH Manual				   ltm monitor diameter(1)

NAME
       diameter - Configures a monitor for Diameter protocol resources.

MODULE
       ltm monitor

SYNTAX
       Configure the diameter component within the ltm monitor module using the syntax in the following sections.

   CREATE/MODIFY
	create diameter [name]
	modify diameter [name]
	  options:
	    acct-application-id [ [integer] | none ]
	    app-service [[string] | none]
	    auth-application-id [ [integer] | none ]
	    defaults-from [name]
	    description [string]
	    host-ip-address [ [ip address] | none]
	    interval [integer]
	    manual-resume [enabled | disabled]
	    mode [tcp | mr-tcp | mr-sctp]
	    origin-host [ [ip address] | none]
	    origin-realm [ [hostname] | none]
	    product-name [name]
	    time-until-up [integer]
	    timeout [integer]
	    up-interval [integer]
	    vendor-id [integer]
	    vendor-specific-acct-application-id [ [integer] | none]
	    vendor-specific-auth-application-id [ [integer] | none]
	    vendor-specific-vendor-id [ [integer] | none]

	edit diameter [ [ [name] | [glob] | [regex] ] ... ]
	    options:
	      all-properties
	      non-default-properties

   DISPLAY
	list diameter
	list diameter [ [ [name] | [glob] | [regex] ] ... ]
	show diameter [ [ [name] | [glob] | [regex] ] ... ]
	show running-config diameter
	show running-config diameter [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    non-default-properties
	    one-line
	    partition

   DELETE
	delete diameter [name]

       Note: You cannot delete default monitors.

DESCRIPTION
       You can use the diameter component to configure a custom monitor, or you can use the default Diameter monitor that the
       Local Traffic Manager provides. This type of monitor checks the health of Diameter protocol resources.

EXAMPLES
       create diameter my_diameter defaults-from diameter

       Creates a monitor named my_diameter that inherits properties from the default Diameter monitor.

       list diameter

       Displays the properties of all of the Diameter monitors.

OPTIONS
       acct-application-id
	    Specifies the ID of the accounting portion of a Diameter application. If you specify this option, you must also
	    specify a value for the auth-application-id option. The default value is none.

	    Note that the acct-application-id and auth-application-id attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and  vendor-specific-acct-application-id AVP are mutually exclusive. You can only specify one of these
	    AVPs.

       app-service
	    Specifies the name of the application service to which the monitor belongs. The default value is none. Note: If the
	    strict-updates option is enabled on the application service that owns the object, you cannot modify or delete the
	    monitor. Only the application service can modify or delete the monitor.

       auth-application-id
	    Specifies the ID of the authentication and authorization portion of a Diameter application. If you specify this
	    option, you must also specify a value for the acct-application-id option. The default value is none.

	    Note that the acct-application-id and auth-application-id attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and  vendor-specific-acct-application-id AVP are mutually exclusive. You can only specify one set of
	    these AVPs.

       defaults-from
	    Specifies the name of the monitor from which you want your custom monitor to inherit settings. The default value is
	    firepass.

       description
	    User defined description.

       glob Displays the items that match the glob expression. See help glob for a description of glob expression syntax.

       host-ip-address
	    Specifies the IP address of the sender of the Diameter message for the Diameter protocol peer discovery feature. The
	    default value is none.

       interval
	    Specifies, in seconds, the frequency at which the system issues the monitor check when either the resource is down or
	    the status of the resource is unknown. The default value is 10 seconds.

	    Important: F5 Networks recommends that when you configure this option and the up-interval option, whichever value is
	    greater be a multiple of the lesser value to allow for an even distribution of monitor checks among all monitors.

       manual-resume
	    Specifies whether the system automatically changes the status of a resource to up at the next successful monitor
	    check. The default value is disabled.

	    Note that if you set the manual-resume option to enabled, you must manually mark the resource as up before the system
	    can use it for load balancing connections.

       mode Specifies the transport protocol that the monitor uses to communicate with the target. The default mode is tcp. The
	    options are:

	    tcp  Specifies that the monitor uses TCP to communicate with the target.

	    mr-tcp
		 Specifies that the monitor uses TCP with the message-routing framework to communicate with the target.

	    mr-sctp
		 Specifies that the monitor uses SCTP with the message-routing framework to communicate with the target.

	    The modes beginning with "mr-" use an in-TMM monitor based on the message-routing framework (MRF). The other modes use
	    the legacy external monitor.

       name Specifies a unique name for the component. This option is required for the commands create, delete, and modify.

       origin-host
	    Specifies the IP address from which the Diameter message originates. The default value is the fully-qualified domain
	    name of the BIG-IP system.

       origin-realm
	    Specifies the realm in which the host from which the Diameter message originates resides. The default value is f5.com.

       partition
	    Displays the administrative partition within which the component resides.

       product-name
	    Specifies the vendor-assigned name of the Diameter application. The value of this option must remain constant across
	    firmware revisions for the same product. The default value is F5 BIGIP Diameter Health Monitoring.

       regex
	    Displays the items that match the regular expression. The regular expression must be preceded by an at sign (@[regular
	    expression]) to indicate that the identifier is a regular expression. See help regex for a description of regular
	    expression syntax.

       time-until-up
	    Specifies the amount of time, in seconds, after the first successful response before a node is marked up. A value of 0
	    (zero) causes a node to be marked up immediately after a valid response is received from the node. The default value
	    is 0 (zero).

       timeout
	    Specifies the number of seconds the target has in which to respond to the monitor request. The default value is 31
	    seconds.

	    If the target responds within the set time period, it is considered up. If the target does not respond within the set
	    time period, it is considered down. Also, if the target responds with a RESET packet, the system immediately flags the
	    target as down without waiting for the timeout interval to expire.

       up-interval
	    Specifies, in seconds, the frequency at which the system issues the monitor check when the resource is up. The default
	    value is 0 (zero), which specifies that the system uses the value of the interval option whether the resource is up or
	    down.

	    Important: F5 Networks recommends that when you configure this option and the interval option, whichever value is
	    greater be a multiple of the lesser value to allow for an even distribution of monitor checks among all monitors.

       vendor-id
	    Specifies the IANA SMI Network Management Private Enterprise Code assigned to the vendor of the Diameter application.
	    The default value is 3375.

       vendor-specific-acct-application-id
	    Specifies the ID of the vendor-specific accounting portion of a Diameter application. If you specify this option, you
	    must also specify a value for the vendor-specific-auth-application-id option. The default value is none.

	    Note that the acct-application-id and auth-application-id attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and  vendor-specific-acct-application-id AVP are mutually exclusive. You can only specify one of these
	    AVPs.

       vendor-specific-auth-application-id
	    Specifies the ID of the vendor-specific authentication and authorization portion of a Diameter application. If you
	    specify this option, you must also specify a value for the vendor-specific-acct-application-id option. The default
	    value is none.

	    Note that the acct-application-id and auth-application-id attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and vendor-specific-acct-application-id AVP are mutually exclusive. You can only specify one of these
	    AVPs.

       vendor-specific-vendor-id
	    Specifies the ID of a vendor-specific Diameter application. The system uses this ID to advertise support for the
	    application. The default value is none.

SEE ALSO
       create, delete, edit, glob, list, modify, regex, show, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or by any means, electronic or mechanical, including
       photocopying, recording, or information storage and retrieval systems, for any purpose other than the purchaser's personal
       use, without the express written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2009-2010, 2012. All rights reserved.

BIG-IP							    2019-10-30					   ltm monitor diameter(1)