ltm monitor icmpΒΆ

ltm monitor icmp(1)					BIG-IP TMSH Manual				       ltm monitor icmp(1)

NAME
       icmp - Configures an Internet Control Message Protocol (ICMP) monitor.

MODULE
       ltm monitor

SYNTAX
       Configure the icmp component within the ltm monitor module using the syntax shown in the following sections.

   CREATE/MODIFY
	create icmp [name]
	modify icmp [name]
	  options:
	    adaptive [enabled | disabled]
	    adaptive-divergence-type [relative | absolute]
	    adaptive-divergence-value [integer]
	    adaptive-limit [integer]
	    adaptive-sampling-timespan [integer]
	    app-service [[string] | none]
	    defaults-from [name]
	    description [string]
	    destination [ip address]
	    interval [integer]
	    manual-resume [enabled | disabled]
	    time-until-up [integer]
	    timeout [integer]
	    transparent [enabled | disabled]
	    up-interval [integer]

	edit icmp [ [ [name] | [glob] | [regex] ] ... ]
	    options:
	      all-properties
	      non-default-properties

   DISPLAY
	list icmp
	list icmp [ [ [name] | [glob] | [regex] ] ... ]
	show icmp [ [ [name] | [glob] | [regex] ] ... ]
	show running-config icmp
	show running-config icmp [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    non-default-properties
	    one-line
	    partition
	    test-result

   DELETE
	delete icmp [name]

       Note: You cannot delete default monitors.

   RUN
	run icmp [name] [destination [ip address]]

   STOP
	stop icmp [name]

DESCRIPTION
       You can use the icmp component to configure a custom monitor, or you can use the default ICMP monitor that the Local
       Traffic Manager provides.

       You can test a custom monitor configuration against a specified target destination by using the run command, and view the
       results of such a test by using the show command with the test-result option.

       The following user roles (in addition to the root user) have permissions to run and stop an ltm monitor test:

	    admin, application-editor, manager, operator, resource-admin

EXAMPLES
       create icmp my_icmp defaults-from icmp

       Creates a monitor named my_icmp that inherits properties from the default ICMP monitor.

       list icmp

       Displays the properties of all of the ICMP monitors.

       run icmp my_icmp destination 10.10.10.10

       Runs a one-shot test of the custom monitor my_icmp against a target node at IP address 10.10.10.10.

       stop icmp my_icmp

       Cancels a one-shot test of the custom monitor my_icmp in progress.

       show icmp my_icmp test-result

       Displays the result of the most recent one-shot test of the custom monitor my_icmp.

OPTIONS
       adaptive
	    Specifies whether the adaptive feature is enabled for this monitor. Not all monitors support the adaptive feature.

       adaptive-divergence-type
	    Specifies whether the adaptive-divergence-value is relative or absolute.

       adaptive-divergence-value
	    Specifies how far from mean latency each monitor probe is allowed to be. If adaptive-divergence-type is relative, this
	    value is a percentage deviation from mean (e.g. 50 would indicate the probe is allowed to exceed the mean latency by
	    50%.)  If adaptive-divergence-type is absolute, this value is an offset from mean in milliseconds (e.g. 250 would
	    indicate the probe is allowed allowed to exceed the mean latency by 250 ms.)  A probe that exceeds latency is counted
	    the same as a probe that is not received, so in the typical scenario, it will require three missed latencies in a row
	    to mark a pool member or node down (i.e. a 15-second interval with a 46-second timeout, would require three missed
	    probes before the pool member or node would be marked down.)

       adaptive-limit
	    Specifies the hard limit, in milliseconds, which the probe is not allowed to exceed, regardless of the divergence
	    value. For example, if this value is 500, then the probe latency may not exceed 500 ms even if that would still fall
	    within the divergence value.

       adaptive-sampling-timespan
	    Specifies the size of the sliding window, in seconds, which records probe history. For example, if this value is 300,
	    then a sliding window of the last five minutes' probe history will be used for calculating probe mean latency and
	    standard deviation.

       app-service
	    Specifies the name of the application service to which the monitor belongs. The default value is none. Note: If the
	    strict-updates option is enabled on the application service that owns the object, you cannot modify or delete the
	    monitor. Only the application service can modify or delete the monitor.

       defaults-from
	    Specifies the name of the monitor from which you want your custom monitor to inherit settings. The default value is
	    icmp.

       description
	    User defined description.

       destination
	    Specifies the IP address of the resource that is the destination of this monitor. The default value is *.

	    Possible values are:

	    *	 Specifies to perform a health check on the IP address of the node.

	    IP address
		 Specifies to perform a health check on the IP address that you specify, and mark the associated node up or down
		 accordingly.

	    IP address (with the transparent option enabled)
		 Specifies to perform a health check on the IP address that you specify, route the check through the IP address of
		 the associated node, and mark the IP address of the associated node up or down accordingly.

	    This option is required for the command run, unless an IP address is specified in the destination option for the
	    custom monitor.

       glob Displays the items that match the glob expression. See help glob for a description of glob expression syntax.

       interval
	    Specifies, in seconds, the frequency at which the system issues the monitor check when either the resource is down or
	    the status of the resource is unknown. The default value is 5 seconds.

	    Important: F5 Networks recommends that when you configure this option and the up-interval option, whichever value is
	    greater be a multiple of the lesser value to allow for an even distribution of monitor checks among all monitors.

       manual-resume
	    Specifies whether the system automatically changes the status of a resource to up at the next successful monitor
	    check. The default value of the manual-resume option is disabled.

	    Note that if you set the manual-resume option to enabled, you must manually mark the resource as up before the system
	    can use it for load balancing connections.

       name Specifies a unique name for the component. This option is required for the commands create, delete, modify, run and
	    stop.

       partition
	    Displays the administrative partition within which the component resides.

       regex
	    Displays the items that match the regular expression. The regular expression must be preceded by an at sign (@[regular
	    expression]) to indicate that the identifier is a regular expression. See help regex for a description of regular
	    expression syntax.

       test-result
	    Displays the result of the most recent one-shot test of the specified monitor(s), if any such test has been performed
	    since BIG-IP was started.

       time-until-up
	    Specifies the amount of time, in seconds, after the first successful response before a node is marked up. A value of 0
	    (zero) causes a node to be marked up immediately after a valid response is received from the node. The default value
	    is 0 (zero).

       timeout
	    Specifies the number of seconds the target has in which to respond to the monitor request. The default value is 16
	    seconds.

	    If the target responds within the set time period, it is considered up. If the target does not respond within the set
	    time period, it is considered down. Also, if the target responds with a RESET packet, the system immediately flags the
	    target as down without waiting for the timeout interval to expire.

       transparent
	    Specifies whether the monitor operates in transparent mode. Monitors in transparent mode can monitor pool members
	    through firewalls. The default value is disabled.

       up-interval
	    Specifies, in seconds, the frequency at which the system issues the monitor check when the resource is up. The default
	    value is 0 (zero), which specifies that the system uses the value of the interval option whether the resource is up or
	    down.

	    Important: F5 Networks recommends that when you configure this option and the interval option, whichever value is
	    greater be a multiple of the lesser value to allow for an even distribution of monitor checks among all monitors.

SEE ALSO
       create, delete, edit, glob, list, modify, regex, run, show, stop, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or by any means, electronic or mechanical, including
       photocopying, recording, or information storage and retrieval systems, for any purpose other than the purchaser's personal
       use, without the express written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2008-2010, 2012-2013, 2016-2017. All rights reserved.

BIG-IP							    2017-04-05					       ltm monitor icmp(1)