ltm monitor diameterΒΆ

ltm monitor diameter(1)       BIG-IP TMSH Manual       ltm monitor diameter(1)



NAME
       diameter - Configures a monitor for Diameter protocol resources.

MODULE
       ltm monitor

SYNTAX
       Configure the diameter component within the ltm monitor module using
       the syntax in the following sections.

   CREATE/MODIFY
	create diameter [name]
	modify diameter [name]
	  options:
	    acct-application-id [ [integer] | none ]
	    app-service [[string] | none]
	    auth-application-id [ [integer] | none ]
	    defaults-from [name]
	    description [string]
	    host-ip-address [ [ip address] | none]
	    interval [integer]
	    manual-resume [enabled | disabled]
	    origin-host [ [ip address] | none]
	    origin-realm [ [hostname] | none]
	    product-name [name]
	    time-until-up [integer]
	    timeout [integer]
	    up-interval [integer]
	    vendor-id [integer]
	    vendor-specific-acct-application-id [ [integer] | none]
	    vendor-specific-auth-application-id [ [integer] | none]
	    vendor-specific-vendor-id [ [integer] | none]

	edit diameter [ [ [name] | [glob] | [regex] ] ... ]
	    options:
	      all-properties
	      non-default-properties

   DISPLAY
	list diameter
	list diameter [ [ [name] | [glob] | [regex] ] ... ]
	show diameter [ [ [name] | [glob] | [regex] ] ... ]
	show running-config diameter
	show running-config diameter [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    non-default-properties
	    one-line
	    partition

   DELETE
	delete diameter [name]

       Note: You cannot delete default monitors.

DESCRIPTION
       You can use the diameter component to configure a custom monitor, or
       you can use the default Diameter monitor that the Local Traffic Manager
       provides. This type of monitor checks the health of Diameter protocol
       resources.

EXAMPLES
       create diameter my_diameter defaults-from diameter

       Creates a monitor named my_diameter that inherits properties from the
       default Diameter monitor.

       list diameter

       Displays the properties of all of the Diameter monitors.

OPTIONS
       acct-application-id
	    Specifies the ID of the accounting portion of a Diameter
	    application. If you specify this option, you must also specify a
	    value for the auth-application-id option. The default value is
	    none.

	    Note that the acct-application-id and auth-application-id
	    attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and  vendor-specific-acct-application-id AVP are
	    mutually exclusive. You can only specify one of these AVPs.

       app-service
	    Specifies the name of the application service to which the monitor
	    belongs. The default value is none. Note: If the strict-updates
	    option is enabled on the application service that owns the object,
	    you cannot modify or delete the monitor. Only the application
	    service can modify or delete the monitor.

       auth-application-id
	    Specifies the ID of the authentication and authorization portion
	    of a Diameter application. If you specify this option, you must
	    also specify a value for the acct-application-id option. The
	    default value is none.

	    Note that the acct-application-id and auth-application-id
	    attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and  vendor-specific-acct-application-id AVP are
	    mutually exclusive. You can only specify one set of these AVPs.

       defaults-from
	    Specifies the name of the monitor from which you want your custom
	    monitor to inherit settings. The default value is firepass.

       description
	    User defined description.

       glob Displays the items that match the glob expression. See help glob
	    for a description of glob expression syntax.

       host-ip-address
	    Specifies the IP address of the sender of the Diameter message for
	    the Diameter protocol peer discovery feature. The default value is
	    none.

       interval
	    Specifies, in seconds, the frequency at which the system issues
	    the monitor check when either the resource is down or the status
	    of the resource is unknown. The default value is 10 seconds.

	    Important: F5 Networks recommends that when you configure this
	    option and the up-interval option, whichever value is greater be a
	    multiple of the lesser value to allow for an even distribution of
	    monitor checks among all monitors.

       manual-resume
	    Specifies whether the system automatically changes the status of a
	    resource to up at the next successful monitor check. The default
	    value is disabled.

	    Note that if you set the manual-resume option to enabled, you must
	    manually mark the resource as up before the system can use it for
	    load balancing connections.

       name Specifies a unique name for the component. This option is required
	    for the commands create, delete, and modify.

       origin-host
	    Specifies the IP address from which the Diameter message
	    originates. The default value is the fully-qualified domain name
	    of the BIG-IP system.

       origin-realm
	    Specifies the realm in which the host from which the Diameter
	    message originates resides. The default value is f5.com.

       partition
	    Displays the administrative partition within which the component
	    resides.

       product-name
	    Specifies the vendor-assigned name of the Diameter application.
	    The value of this option must remain constant across firmware
	    revisions for the same product. The default value is F5 BIGIP
	    Diameter Health Monitoring.

       regex
	    Displays the items that match the regular expression. The regular
	    expression must be preceded by an at sign (@[regular expression])
	    to indicate that the identifier is a regular expression. See help
	    regex for a description of regular expression syntax.

       time-until-up
	    Specifies the amount of time, in seconds, after the first
	    successful response before a node is marked up. A value of 0
	    (zero) causes a node to be marked up immediately after a valid
	    response is received from the node. The default value is 0 (zero).

       timeout
	    Specifies the number of seconds the target has in which to respond
	    to the monitor request. The default value is 31 seconds.

	    If the target responds within the set time period, it is
	    considered up. If the target does not respond within the set time
	    period, it is considered down. Also, if the target responds with a
	    RESET packet, the system immediately flags the target as down
	    without waiting for the timeout interval to expire.

       up-interval
	    Specifies, in seconds, the frequency at which the system issues
	    the monitor check when the resource is up. The default value is 0
	    (zero), which specifies that the system uses the value of the
	    interval option whether the resource is up or down.

	    Important: F5 Networks recommends that when you configure this
	    option and the interval option, whichever value is greater be a
	    multiple of the lesser value to allow for an even distribution of
	    monitor checks among all monitors.

       vendor-id
	    Specifies the IANA SMI Network Management Private Enterprise Code
	    assigned to the vendor of the Diameter application. The default
	    value is 3375.

       vendor-specific-acct-application-id
	    Specifies the ID of the vendor-specific accounting portion of a
	    Diameter application. If you specify this option, you must also
	    specify a value for the vendor-specific-auth-application-id
	    option. The default value is none.

	    Note that the acct-application-id and auth-application-id
	    attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and  vendor-specific-acct-application-id AVP are
	    mutually exclusive. You can only specify one of these AVPs.

       vendor-specific-auth-application-id
	    Specifies the ID of the vendor-specific authentication and
	    authorization portion of a Diameter application. If you specify
	    this option, you must also specify a value for the vendor-
	    specific-acct-application-id option. The default value is none.

	    Note that the acct-application-id and auth-application-id
	    attribute-value-pair (AVP), and the vendor-specific-auth-
	    application-id  and vendor-specific-acct-application-id AVP are
	    mutually exclusive. You can only specify one of these AVPs.

       vendor-specific-vendor-id
	    Specifies the ID of a vendor-specific Diameter application. The
	    system uses this ID to advertise support for the application. The
	    default value is none.

SEE ALSO
       create, delete, edit, glob, list, modify, regex, show, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or
       by any means, electronic or mechanical, including photocopying,
       recording, or information storage and retrieval systems, for any
       purpose other than the purchaser's personal use, without the express
       written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2009-2010, 2012. All rights
       reserved.



BIG-IP				  2016-06-16	       ltm monitor diameter(1)