ltm monitor httpsΒΆ

ltm monitor https(1)	      BIG-IP TMSH Manual	  ltm monitor https(1)



NAME
       https - Configures a Hypertext Transfer Protocol over Secure Socket
       Layer (HTTPS) monitor.

MODULE
       ltm monitor

SYNTAX
       Configure the https component within the ltm monitor module using the
       syntax in the following sections.

   CREATE/MODIFY
	create https [name]
	modify https [name]
	  options:
	    adaptive [enabled | disabled]
	    adaptive-divergence-type [relative | absolute]
	    adaptive-divergence-value [integer]
	    adaptive-limit [integer]
	    adaptive-sampling-timespan [integer]
	    app-service [[string] | none]
	    cert [ [cert list] | none]
	    cipherlist [string]
	    compatibility [enabled | disabled]
	    defaults-from [name]
	    description [string]
	    destination [ip address][port]
	    interval [integer]
	    ip-dscp [integer]
	    key [ [key] | none]
	    manual-resume [enabled | disabled]
	    password [none | [password] ]
	    recv [none | [string] ]
	    recv-disable [none | [string] ]
	    reverse [enabled | disabled]
	    send [none | [string] ]
	    time-until-up [integer]
	    timeout [integer]
	    transparent [enabled | disabled]
	    up-interval [integer]
	    username [ [name] | none]

	edit https [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    non-default-properties

   DISPLAY
	list https
	list https [ [ [name] | [glob] | [regex] ] ... ]
	show https [ [ [name] | [glob] | [regex] ] ... ]
	show running-config https
	show running-config https [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    non-default-properties
	    one-line
	    partition

   DELETE
	delete https [name]

       Note: You cannot delete default monitors.

DESCRIPTION
       You can use the https component to configure a custom monitor, or you
       can use the default HTTPS monitor that the Local Traffic Manager
       provides. This type of monitor verifies the HTTPS service by attempting
       to receive specific content from a Web page protected by Secure Socket
       Layer (SSL) security.

       Note that one of the pre-configured HTTPS monitors is named https_443,
       which performs a health check on a server using the IP address supplied
       by the pool member and port 443.

EXAMPLES
       create https my_https defaults-from https

       Creates a monitor named my_https that inherits properties from the
       default HTTPS monitor.

       list https

       Displays the properties of all of the HTTPS monitors.

OPTIONS
       adaptive
	    Specifies whether the adaptive feature is enabled for this
	    monitor. Not all monitors support the adaptive feature.

       adaptive-divergence-type
	    Specifies whether the adaptive-divergence-value is relative or
	    absolute.

       adaptive-divergence-value
	    Specifies how far from mean latency each monitor probe is allowed
	    to be. If adaptive-divergence-type is relative, this value is a
	    percentage deviation from mean (e.g. 50 would indicate the probe
	    is allowed to exceed the mean latency by 50%.)  If adaptive-
	    divergence-type is absolute, this value is an offset from mean in
	    milliseconds (e.g. 250 would indicate the probe is allowed allowed
	    to exceed the mean latency by 250 ms.)  A probe that exceeds
	    latency is counted the same as a probe that is not received, so in
	    the typical scenario, it will require three missed latencies in a
	    row to mark a pool member or node down (i.e. a 15-second interval
	    with a 46-second timeout, would require three missed probes before
	    the pool member or node would be marked down.)

       adaptive-limit
	    Specifies the hard limit, in milliseconds, which the probe is not
	    allowed to exceed, regardless of the divergence value. For
	    example, if this value is 500, then the probe latency may not
	    exceed 500 ms even if that would still fall within the divergence
	    value.

       adaptive-sampling-timespan
	    Specifies the size of the sliding window, in seconds, which
	    records probe history. For example, if this value is 300, then a
	    sliding window of the last five minutes' probe history will be
	    used for calculating probe mean latency and standard deviation.

       app-service
	    Specifies the name of the application service to which the monitor
	    belongs. The default value is none. Note: If the strict-updates
	    option is enabled on the application service that owns the object,
	    you cannot modify or delete the monitor. Only the application
	    service can modify or delete the monitor.

       cert Specifies a file object for a client certificate that the monitor
	    sends to the target SSL server. The default value is none.

       cipherlist
	    Specifies the list of ciphers for this monitor. The default list
	    DEFAULT:+SHA:+3DES:+kEDH is located in the file
	    base_monitors.conf.

       compatibility
	    Specifies, when enabled, that the SSL options setting (in OpenSSL)
	    is set to ALL. The default value is enabled.

       defaults-from
	    Specifies the name of the monitor from which you want your custom
	    monitor to inherit settings. The default value is https.

       description
	    User defined description.

       destination
	    Specifies the IP address and service port of the resource that is
	    the destination of this monitor. The default value is *:*.

	    Possible values are:

	    *:*  Specifies to perform a health check on the IP address and
		 port supplied by a pool member.

	    *:port
		 Specifies to perform a health check on the server with the IP
		 address supplied by the pool member and the port you specify.

	    IP address:port
		 Specifies to mark a pool member up or down based on the
		 response of the server at the IP address and port you
		 specify.

	    IP address:port (with the transparent option enabled)
		 Specifies to perform a health check on the server at the IP
		 address and port specified in the monitor, routing the check
		 through the IP address and port supplied by the pool member.
		 The pool member (the gateway) is marked up or down
		 accordingly.

       glob Displays the items that match the glob expression. See help glob
	    for a description of glob expression syntax.

       interval
	    Specifies, in seconds, the frequency at which the system issues
	    the monitor check when either the resource is down or the status
	    of the resource is unknown. The default value is 5 seconds.

	    Important: F5 Networks recommends that when you configure this
	    option and the up-interval option, whichever value is greater be a
	    multiple of the lesser value to allow for an even distribution of
	    monitor checks among all monitors.

       ip-dscp
	    Specifies the differentiated services code point (DSCP). DSCP is a
	    6-bit value in the Differentiated Services (DS) field of the IP
	    header. It can be used to specify the quality of service desired
	    for the packet. The valid range for this value is 0 to 63 (hex 0x0
	    to 0x3f). The default value is zero.

       key  Specifies the RSA private key if the monitored target requires
	    authentication. The key must be surrounded by quotation marks, for
	    example, key \"client.key\". Note that if you specify a key, you
	    must also specify a value for the cert option. The default value
	    is none.

       manual-resume
	    Specifies whether the system automatically changes the status of a
	    resource to up at the next successful monitor check. The default
	    value of the manual-resume option is disabled.

	    Note that if you set the manual-resume option to enabled, you must
	    manually mark the resource as up before the system can use it for
	    load balancing connections.

       name Specifies a unique name for the component. This option is required
	    for the commands create, delete, and modify.

       partition
	    Displays the administrative partition within which the component
	    resides.

       password
	    Specifies the password if the monitored target requires
	    authentication. The default value is none.

       recv Specifies the text string that the monitor looks for in the
	    returned resource. The default value is none.

	    The most common receive expressions contain a text string that is
	    included in an HTML file on your site. The text string can be
	    regular text, HTML tags, or image names, and the associated
	    operation is not case-sensitive. If you do not specify a value for
	    both the send and recv options, the monitor performs a simple
	    service check and connect only.

       recv-disable
	    Specifies a text string that the monitor looks for in the returned
	    resource. If the text string is matched in the returned resource,
	    the corresponding node or pool member is marked session disabled.
	    The default value is none.

	    You specify a recv-disable string in the same way that you specify
	    a recv string.

	    If you specify a recv-disable string, you must also specify a recv
	    string. You cannot specify a recv-disable string, if the reverse
	    option is enabled.

       regex
	    Displays the items that match the regular expression. The regular
	    expression must be preceded by an at sign (@[regular expression])
	    to indicate that the identifier is a regular expression. See help
	    regex for a description of regular expression syntax.

       reverse
	    Specifies whether the monitor operates in reverse mode. When the
	    monitor is in reverse mode, a successful check marks the monitored
	    object down instead of up. You can use the this mode only if you
	    configure both the send and recv options.

	    The default value is disabled, which specifies that the monitor
	    does not operate in reverse mode. The enabled value specifies that
	    the monitor operates in reverse mode.

       send Specifies the text string that the monitor sends to the target
	    object.

	    The default setting is GET /, which retrieves a default HTML file
	    for a web site. To retrieve a specific page from a web site,
	    specify a fully-qualified path name, for example, GET
	    /www/company/index.html.

	    Since the string may have special characters, the system may
	    require that the string be enclosed with single quotation marks.

	    If this value is null, then a valid connection suffices to
	    determine that the service is up. In this case, the system does
	    not need the recv option and ignores the option even if not null.

       time-until-up
	    Specifies the amount of time, in seconds, after the first
	    successful response before a node is marked up. A value of 0
	    (zero) causes a node to be marked up immediately after a valid
	    response is received from the node. The default value is 0 (zero).

       timeout
	    Specifies the number of seconds the target has in which to respond
	    to the monitor request. The default value is 16 seconds.

	    If the target responds within the set time period, it is
	    considered up. If the target does not respond within the set time
	    period, it is considered down. Also, if the target responds with a
	    RESET packet, the system immediately flags the target as down
	    without waiting for the timeout interval to expire.

       transparent
	    Specifies whether the monitor operates in transparent mode.
	    Monitors in transparent mode can monitor pool members through
	    firewalls. The default value is disabled.

       up-interval
	    Specifies, in seconds, the frequency at which the system issues
	    the monitor check when the resource is up. The default value is 0
	    (zero), which specifies that the system uses the value of the
	    interval option whether the resource is up or down.

	    Important: F5 Networks recommends that when you configure this
	    option and the interval option, whichever value is greater be a
	    multiple of the lesser value to allow for an even distribution of
	    monitor checks among all monitors.

       username
	    Specifies the username, if the monitored target requires
	    authentication. The default value is none.

SEE ALSO
       create, delete, edit, glob, list, modify, regex, show, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or
       by any means, electronic or mechanical, including photocopying,
       recording, or information storage and retrieval systems, for any
       purpose other than the purchaser's personal use, without the express
       written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2008-2010, 2012-2013, 2016. All
       rights reserved.



BIG-IP				  2016-03-14		  ltm monitor https(1)