sys sflow global-settings system
sys sflow global-settings systBIG-IP TMSH Msysasflow global-settings system(1)
NAME
system - Manages the global system sFlow configuration on the BIG-IP
system.
MODULE
sys sflow global-settings
SYNTAX
Configure the system component within the sys sflow global-settings
module using the syntax shown in the following sections.
MODIFY
modify system
options:
description [string]
poll-interval [integer]
DISPLAY
list system
options:
all-properties
non-default-properties
one-line
DESCRIPTION
You can use the system component to modify or list the global system
sFlow configuration on the BIG-IP system.
Note: You can modify the global system sFlow configuration on the BIG-
IP system, only if you are assigned either the Resource Administrator
or Administrator user role.
EXAMPLES
modify system poll-interval 60
Sets the poll-interval to 60 seconds for the system data sources on the
BIG-IP system.
OPTIONS
description
User defined description.
poll-interval
Specifies the maximum interval in seconds between polling by the
sFlow agent of the system data sources on the BIG-IP system. The
default value is 10.
SEE ALSO
list, modify, tmsh
COPYRIGHT
No part of this program may be reproduced or transmitted in any form or
by any means, electronic or mechanical, including photocopying,
recording, or information storage and retrieval systems, for any
purpose other than the purchaser's personal use, without the express
written permission of F5 Networks, Inc.
F5 Networks and BIG-IP (c) Copyright 2008-2013. All rights reserved.
BIG-IP 2013-10-1sys sflow global-settings system(1)