sys failoverΒΆ

sys failover(1) 	      BIG-IP TMSH Manual	       sys failover(1)



NAME
       failover -  Configures failover for a BIG-IP(r) unit in a redundant
       system configuration.

MODULE
       sys

SYNTAX
       Change the failover state within the sys module using the syntax in the
       following section.

   MODIFY
	run failover
	   options:
	     device [string]
	     no-persist
	     offline
	     online
	     persist
	     standby
	     traffic-group [[string] | default | non-default | none]

   DISPLAY
	show failover
	 options:
	   cable

DESCRIPTION
       Failover is the process where a standby unit in a redundant system
       configuration takes over when a software or hardware failure is
       detected on the active unit.

EXAMPLES
       run failover standby

       Causes the active unit or cluster to go into the standby state forcing
       the other unit or cluster in the redundant system configuration to
       become active.

       run failover offline

       Causes the active unit or cluster to go into the Forced Offline state.

       run failover online

       Changes the status of a unit or cluster from Forced Offline to either
       Active or Standby, depending upon the status of the other unit or
       cluster in a redundant system configuration.

       show failover

       Displays the failover state of the BIG-IP system (active, standby,
       offline, forced_offline) and how long it has been in that state.

       run failover standby device my_bigip

       Specifies that the my_bigip device should become the active device for
       all traffic groups currently active on this device.

       run failover standby traffic-group traffic_grp01

       Specifies that the traffic group named traffic_grp01 should fail over
       to the Standby state. The traffic group will then become Active on
       another device.

       run sys failover offline no-persist

       Changes the status of a unit to Forced Offline and indicates that the
       change will not be persisted after a system restart.

       run sys failover offline persist

       Changes the status of a unit to Forced Offline and indicates that the
       change will be persisted after a system restart.

OPTIONS
       Use these options to control failover of the system:

       device
	    Specifies the device that should next become the active device for
	    the specified traffic group or all traffic groups (if a traffic
	    group is not specified). This option may only be specified with
	    the standby option.

       no-persist
	    Does not persist the change in status of a unit. The option is
	    valid only with the offline state.

       offline
	    Changes the status of a unit or cluster to Forced Offline. If
	    persist or no-persist options are not specified, the default
	    action is to persist the offline status of the unit between system
	    restarts.

       online
	    Changes the status of a unit or cluster from Forced Offline to
	    either Active or Standby, depending upon the status of the other
	    unit or cluster in a redundant system configuration.

       persist
	    Persists the change in status of a unit. The option is valid only
	    with the offline state.

       standby
	    Specifies that the active unit or cluster fails over to a Standby
	    state, causing the standby unit or cluster to become Active.

       traffic-group
	    Specifies the traffic-group that should fail over to the Standby
	    state, the traffic-group will become Active on another device.
	    This option may only be specified with the standby option.

       Use this option to display the failover cable status of the system:

       cable
	    Displays the status that the failover daemon detects on the serial
	    cable from its failover peer. It also shows what the failover peer
	    detects on the serial cable. An active BIG-IP system will see a
	    zero from its failover peer. A standby BIG-IP system will see a
	    one from its failover peer.

SEE ALSO
       run, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or
       by any means, electronic or mechanical, including photocopying,
       recording, or information storage and retrieval systems, for any