sys integrity status-checkΒΆ

sys integrity status-check(1) BIG-IP TMSH Manual sys integrity status-check(1)



NAME
       status-check - Checks and verifies the integrity of the BIG-IP BIOS and
       kernel using the tpm-status utility.

MODULE
       sys integrity

SYNTAX
       Run a check on the system's integrity status in the sys integrity
       module by using the syntax below.

   RUN
	 run status-check
	   options:
	     -h Print help for the tpm-status command.
	     -c Attempt to continue after reaching an error.
	     -o  Output the PCR measurements to a given file after measurement. The file will be overwritten if pre-existing.
	     -a  Append the PCR measurements to a given file after measurement.
	     -v [0|1|2|3] Modify the verbosity of the tpm-status utility from 0 (not verbose) to 3 (very very verbose). Default value: 0.
	     -q Generates a file containing system information needed for Remote Attestation. File is located at /var/log/pcrs.json.
	     Note: Options -o and -a are mutually exclusive. Files may only be written to areas allowed by tmsh.

DESCRIPTION
       You can use the status-check command to check the system's integrity
       status.

EXAMPLES
       run status-check

       Runs the tpm-status utility and returns the integrity status. It shall
       be one of VALID, INVALID, UNAVAILABLE, or PENDING.

       run status-check -v 3

       Runs the tpm-status utility with very very verbose output then returns
       the integrity status.

SEE ALSO
       run, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or
       by any means, electronic or mechanical, including photocopying,
       recording, or information storage and retrieval systems, for any
       purpose other than the purchaser's personal use, without the express
       written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2009-2013, 2017. All rights
       reserved.



BIG-IP				  2018-05-07	 sys integrity status-check(1)