ltm monitor wapΒΆ

ltm monitor wap(1)				  BIG-IP TMSH Manual				   ltm monitor wap(1)

NAME
       wap - Configures a Wireless Application Protocol (WAP) monitor.

MODULE
       ltm monitor

SYNTAX
       Configure the wap component within the ltm monitor module using the syntax in the following sections.

   CREATE/MODIFY
	create wap [name]
	modify wap [name]
	  options:
	    accounting-node [none | [RADIUS server name] ]
	    accounting-port [[integer] | none]
	    app-service [[string] | none]
	    call-id [none | [RADIUS server 11 digit phone number] ]
	    debug [no | yes]
	    defaults-from [name]
	    description [string]
	    destination [ [ ipv4 address[:port] ] | [ ipv6 address[.port] ] ]
	    framed-address [none | [RADIUS framed IP address] ]
	    interval [integer]
	    manual-resume [enabled | disabled]
	    recv [none | [string] ]
	    secret [none | [password] ]
	    send [none | [string]]
	    server-id [none | [RADIUS NAS-ID] ]
	    session-id [none | [RADIUS session ID] ]
	    time-until-up [integer]
	    timeout [integer]
	    up-interval [integer]

	edit wap [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    non-default-properties

   DISPLAY
	list wap
	list wap [ [ [name] | [glob] | [regex] ] ... ]
	show wap [ [ [name] | [glob] | [regex] ] ... ]
	show running-config wap
	show running-config wap [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    non-default-properties
	    one-line
	    partition
	    test-result

   DELETE
	delete wap [name]

       Note: You cannot delete default monitors.

   RUN
	run wap [name] [ destination [ [ ipv4 address[:port] ] | [ ipv6 address[.port] ] ] ]

   STOP
	stop wap [name]

DESCRIPTION
       You can use the wap component to configure a custom monitor, or you can use the default WAP monitor that the
       Local Traffic Manager provides. This type of monitor requests the URL specified in the send option, and finds
       the string specified in the recv option somewhere in the data returned by the URL response.

       You can test a custom monitor configuration against a specified target destination by using the run command,
       and view the results of such a test by using the show command with the test-result option.

       The following user roles (in addition to the root user) have permissions to run and stop an ltm monitor test:

	    admin, application-editor, manager, operator, resource-admin

EXAMPLES
       create wap my_wap defaults-from wap

       Creates a monitor named my_wap that inherits properties from the default WAP monitor.

       list wap

       Displays the properties of all of the WAP monitors.

       run wap my_wap destination 10.10.10.10:80

       Runs a one-shot test of the custom monitor my_wap against a target node at 10.10.10.10:80.

       stop wap my_wap

       Cancels a one-shot test of the custom monitor my_wap in progress.

       show wap my_wap test-result

       Displays the result of the most recent one-shot test of the custom monitor my_wap.

OPTIONS
       accounting-node
	    Specifies the RADIUS server that provides authentication for the WAP target. Note that if you configure
	    the accounting-port option, but you do not configure the this option, the system assumes that the RADIUS
	    server and the WAP server are the same system.

       accounting-port
	    Specifies the port that the monitor uses for RADIUS accounting. The default value is none. A value of 0
	    (zero) disables RADIUS accounting.

       app-service
	    Specifies the name of the application service to which the monitor belongs. The default value is none.
	    Note: If the strict-updates option is enabled on the application service that owns the object, you cannot
	    modify or delete the monitor. Only the application service can modify or delete the monitor.

       call-id
	    Specifies the 11-digit phone number for the RADIUS server. The default value is none.

       debug
	    Specifies whether the monitor sends error messages and additional information to a log file created and
	    labeled specifically for this monitor. You can use the log information to help diagnose and troubleshoot
	    unsuccessful health checks. The default value is no.

	    The options are:

	    no	 Specifies that the system does not redirect error messages and additional information related to
		 this monitor.

	    yes  Specifies that the system redirects error messages and additional information to the
		 /var/log/monitors/--.log file.

       defaults-from
	    Specifies the name of the monitor from which you want your custom monitor to inherit settings. The
	    default value is wap.

       description
	    User defined description.

       destination
	    Specifies the IP address and service port of the resource that is the destination of this monitor. The
	    default value is *:*.

	    Possible values are:

	    *:*  Specifies to perform a health check on the IP address and port supplied by a pool member.

	    *:port
		 Specifies to perform a health check on the server with the IP address supplied by the pool member
		 and the port you specify.

	    IP address:port
		 Specifies to mark a pool member up or down based on the response of the server at the IP address and
		 port you specify.

	    This option is required for the command run, unless an IP address and service port are specified in the
	    destination option for the specified custom monitor.

       glob Displays the items that match the glob expression. See help glob for a description of glob expression
	    syntax.

       framed-address
	    Specifies the RADIUS framed IP address. The default value is none.

       interval
	    Specifies, in seconds, the frequency at which the system issues the monitor check when either the
	    resource is down or the status of the resource is unknown. The default value is 10 seconds.

	    Important: F5 Networks recommends that when you configure this option and the up-interval option,
	    whichever value is greater be a multiple of the lesser value to allow for an even distribution of monitor
	    checks among all monitors.

       manual-resume
	    Specifies whether the system automatically changes the status of a resource to up at the next successful
	    monitor check. The default value of the manual-resume option is disabled.

	    Note that if you set the manual-resume option to enabled, you must manually mark the resource as up
	    before the system can use it for load balancing connections.

       name Specifies a unique name for the component. This option is required for the commands create, delete,
	    modify, run and stop.

       partition
	    Displays the administrative partition within which the component resides.

       recv Specifies the text string that the monitor looks for in the returned resource. The most common receive
	    expressions contain a text string that is included in an HTML file on your site. The text string can be
	    regular text, HTML tags, or image names. If you do not specify both a value for both the send and recv
	    options, the monitor performs a simple service check and connect only. The default value is none.

       regex
	    Displays the items that match the regular expression. The regular expression must be preceded by an at
	    sign (@[regular expression]) to indicate that the identifier is a regular expression. See help regex for
	    a description of regular expression syntax.

       secret
	    Specifies the password the monitor needs to access the resource. The default value is none.

       send Specifies the text string that the monitor sends to the target object. The default setting is GET /,
	    which retrieves a default HTML file for a web site.

	    To retrieve a specific page from a web site, specify a fully-qualified path name, for example, GET
	    /www/company/index.html. Since the string may have special characters, the system may require that the
	    string be enclosed with single quotation marks.

	    If this value is null, then a valid connection suffices to determine that the service is up. In this
	    case, the system does not need the recv option and ignores the option even if it is not null. The default
	    value is none.

       server-id
	    Specifies the RADIUS NAS-ID for this system when configuring a RADIUS server. The default value is none.

       session-id
	    Specifies the RADIUS session identification number when configuring a RADIUS server. The default value is
	    none.

       test-result
	    Displays the result of the most recent one-shot test of the specified monitor(s), if any such test has
	    been performed since BIG-IP was started.

       time-until-up
	    Specifies the amount of time, in seconds, after the first successful response before a node is marked up.
	    A value of 0 (zero) causes a node to be marked up immediately after a valid response is received from the
	    node. The default value is 0 (zero).

       timeout
	    Specifies the number of seconds the target has in which to respond to the monitor request. The default
	    value is 31 seconds.

	    If the target responds within the set time period, it is considered up. If the target does not respond
	    within the set time period, it is considered down. Also, if the target responds with a RESET packet, the
	    system immediately flags the target as down without waiting for the timeout interval to expire.

       up-interval
	    Specifies, in seconds, the frequency at which the system issues the monitor check when the resource is
	    up. The default value is 0 (zero), which specifies that the system uses the value of the interval option
	    whether the resource is up or down.

	    Important: F5 Networks recommends that when you configure this option and the interval option, whichever
	    value is greater be a multiple of the lesser value to allow for an even distribution of monitor checks
	    among all monitors.

SEE ALSO
       create, delete, edit, glob, list, modify, regex, run, show, stop, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or by any means, electronic or
       mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose
       other than the purchaser's personal use, without the express written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2008-2010, 2012-2014, 2017. All rights reserved.

BIG-IP						      2017-08-16				   ltm monitor wap(1)