sys icall istats-triggerΒΆ

sys icall istats-trigger(1)			  BIG-IP TMSH Manual			  sys icall istats-trigger(1)

NAME
       istats-trigger - Configure an iStats trigger to generate a user defined event for the iCall feature on the
       BIG-IP(r) system.

MODULE
       sys icall

SYNTAX
       Modify the istats-trigger component within the sys icall module using the syntax shown in the following
       sections.

   CREATE/MODIFY
	create istats-trigger [name]
	modify istats-trigger [name]
	 options:
	  description [string]
	  duration [integer]
	  event-name [string]
	  istats-key [string]
	  range-max [integer]
	  range-min [integer]
	  repeat [integer]

	mv istats-trigger [ [ [source-name] [destination-name] ]    |
			    [ [name] to-folder [folder-name] ]	    |
			    [ [name...name] to-folder [folder-name] ] ]
	  options:
	    to-folder

   DISPLAY
	list istats-trigger
	list istats-trigger [ [ [name] | [glob] | [regex] ] ... ]

   DELETE
	delete istats-trigger [name]

DESCRIPTION
       You can create an istats-trigger to automatically generate a Control Plane iRules event under the conditions
       specified in the properties.

EXAMPLES
       mv istats-trigger /Common/my_istats_trigger to-folder /Common/my_folder

       Moves an istats-trigger named my_istats_trigger to a folder named my_folder, where my_folder has already been
       created and exists within /Common.

OPTIONS
       description
	    A user defined description of the item.

       duration
	    Duration in seconds. The value "0" means trigger instantly when in range.

       event-name
	    The name of the event that will be generated.

       istats-key
	    Specify the items and thresholds to define when this istats-trigger will generate an event.

       range-max
	    Trigger event only if value is less-than-or-equal to range-max.

       range-min
	    Trigger event only if value is greater-than-or-equal to range-min. Note that if 0 is included in the
	    specified range, then the iStats key must be explicitly initialized with "istats set [key] 0" in order
	    for the trigger to fire.

       repeat
	    Repeat interval in seconds. The value "none" means do not resend the event unless the value falls outside
	    the range and then re-enters it.

       to-folder
	    An istats-trigger can be moved to any folder under /Common, but configuration dependencies may restrict
	    it from moving out of /Common.

SEE ALSO
       create, delete, edit, list, modify, mv, show, sys icall event, sys icall event-handler, sys icall script, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or by any means, electronic or
       mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose
       other than the purchaser's personal use, without the express written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2009-2013, 2016. All rights reserved.

BIG-IP						      2016-03-14			  sys icall istats-trigger(1)