sys sflow receiverΒΆ

sys sflow receiver(1)				  BIG-IP TMSH Manual				sys sflow receiver(1)

NAME
       receiver - Manages sFlow receivers configured on the BIG-IP system.

MODULE
       sys sflow

SYNTAX
       Configure the receiver component within the sys sflow module using the syntax shown in the following sections.

   CREATE/MODIFY
	create receiver [name]
	modify receiver [name]
	  options:
	   address [ip address]
	   app-service [[string] | none]
	   description [string]
	   max-datagram-size [integer]
	   port [ip port]
	   state [disabled | enabled]

   DISPLAY
	list receiver
	list receiver [ [ [name] | [glob] | [regex] ] ... ]
	  options:
	    all-properties
	    one-line

   DELETE
	delete receiver [name]

DESCRIPTION
       You can use the receiver component to create, delete, list, or modify an sFlow receiver object on the BIG-IP
       system.

       Note: You can add an sFlow receiver to the BIG-IP system, only if you are assigned either the Resource
       Administrator or Administrator user role.

EXAMPLES
       create receiver my_receiver address 10.10.10.10

       Creates an sFlow receiver object named my_receiver with an IP address of 10.10.10.10, where the port, max-
       datagram-size, and state options are set to default values.

       create receiver my_receiver address 10.20.10.20 port 1234 state enabled

       Creates an sFlow receiver object named my_receiver with an IP address of 10.20.10.20, a port of 1234, and the
       max-datagram-size option set to default value. The state of the receiver is enabled.

       modify receiver my_receiver state enabled

       Changes the state of sFlow receiver object named my_receiver to enabled.

OPTIONS
       address
	    Specifies the IP address on which the sFlow receiver listens for UDP datagrams. This option is required
	    for the create command.

       app-service
	    Specifies the name of the application service to which the object belongs. The default value is none.
	    Note: If the strict-updates option is enabled on the application service that owns the object, you cannot
	    modify or delete the object. Only the application service can modify or delete the object.

       description
	    User defined description.

       glob Displays the items that match the glob expression. See help glob for a description of glob expression
	    syntax.

       max-datagram-size
	    Specifies the maximum size in bytes of the UDP datagram the sFlow receiver accepts. The default value is
	    1400.

       name Specifies a unique name for the component. This option is required for the commands create, delete, and
	    modify.

       port Specifies the port on which the sFlow receiver listens for UDP datagrams. The default value is the
	    standard sFlow port, 6343.

       regex
	    Displays the items that match the regular expression. The regular expression must be preceded by an at
	    sign (@[regular expression]) to indicate that the identifier is a regular expression. See help regex for
	    a description of regular expression syntax.

       state
	    Specifies the state of the receiver. The sFlow samples will be collected and sent to the receiver when
	    enabled. The default value is disabled.

SEE ALSO
       create, delete, glob, list, modify, regex, tmsh

COPYRIGHT
       No part of this program may be reproduced or transmitted in any form or by any means, electronic or
       mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose
       other than the purchaser's personal use, without the express written permission of F5 Networks, Inc.

       F5 Networks and BIG-IP (c) Copyright 2008-2013. All rights reserved.

BIG-IP						      2014-03-18				sys sflow receiver(1)