APIRef_tm_ltm_monitor_icmp¶

mgmt/tm/ltm/monitor/icmp

/tm/ltm/monitor

ICMP monitor configuration.

REST Endpoints

Collection URI
/mgmt/tm/ltm/monitor/icmp
Collection Methods
OPTIONS, GET
Resource URI
/mgmt/tm/ltm/monitor/icmp/~resource id
Resource Methods
OPTIONS, GET, PUT, PATCH, DELETE, POST
Resource Natural Key
name, partition, subPath

Properties

Name Type Default Value Required Access Description
adaptive string disabled optional read/write Specifies whether the adaptive feature is enabled for this monitor. Not all monitors support the adaptive feature.
adaptiveDivergenceType string relative optional read/write Specifies whether the adaptive-divergence-value is relative or absolute.
adaptiveDivergenceValue integer   optional read/write Specifies how far from mean latency each monitor probe is allowed to be. If adaptive-divergence-type is relative, this value is a percentage deviation from mean (e.g. 50 would indicate the probe is allowed to exceed the mean latency by 50%.) If adaptive-divergence-type is absolute, this value is an offset from mean in milliseconds (e.g. 250 would indicate the probe is allowed to exceed the mean latency by 250 ms.)
adaptiveLimit integer   optional read/write Specifies the hard limit, in milliseconds, which the probe is not allowed to exceed, regardless of the divergence value. For example, if this value is 500, then the probe latency may not exceed 500 ms even if that would still fall within the divergence value.
adaptiveSamplingTimespan integer   optional read/write Specifies the size of the sliding window, in seconds, which records probe history. For example, if this value is 300, then a sliding window of the last five minutes’ probe history will be used for calculating probe mean latency.
appService string   optional read/write The application service to which the object belongs.
defaultsFrom string   optional read/write Specifies the existing monitor from which the system imports settings for the new monitor.
description string   optional read/write User defined description.
destination string   optional read/write Specifies the IP address of the resource that is the destination of this monitor. Possible values are: * (Specifies to perform a health check on the IP address of the node), <IP> (Specifies to perform a health check on the IP address that you specify, and mark the associated node up or down as a result of the response.), and <IP> (with the transparent option enabled) (Specifies to perform a health check on the IP address you specify, and route the check through the associated node IP address, and mark the associated node IP address up or down accordingly.).
interval integer   optional read/write Specifies the frequency at which the system issues the monitor check. The default value is 5 seconds.
manualResume string   optional read/write Specifies whether the system automatically changes the status of a resource to enabled at the next successful monitor check. The default value is disabled. If you set this option to enabled, you must manually re-enable the resource before the system can use it for load balancing connections.
tmPartition string   optional read/write Displays the administrative partition within which the monitor resides.
timeUntilUp integer   optional read/write Specifies the amount of time in seconds after the first successful response before a node will be marked up. A value of 0 will cause a node to be marked up immediately after a valid response is received from the node. The default setting is 0.
timeout integer   optional read/write Specifies the number of seconds the target has in which to respond to the monitor request. The default value is 16 seconds. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. Also, if the target responds with a RESET packet, the system immediately flags the target as down without waiting for the timeout interval to expire.
transparent string   optional read/write Specifies whether the monitor operates in transparent mode. Monitors in transparent mode can monitor pool members through firewalls. The default value is disabled.
upInterval integer   optional read/write Specifies how often in seconds that the system issues the monitor check when the node is up. The default value is the same as the (down) interval.
Copyright (c) 2016, F5 Networks Inc. All Rights Reserved.

The BIG-IP API Reference documentation contains community-contributed content. F5 does not monitor or control community code contributions. We make no guarantees or warranties regarding the available code, and it may contain errors, defects, bugs, inaccuracies, or security vulnerabilities. Your access to and use of any code available in the BIG-IP API reference guides is solely at your own risk.