LocalLB::ProfileTrafficAcceleration::set_time_wait_timeout

Introduced : BIG-IP_v13.0.0
Sets the time wait timeouts for the specified profiles. The time wait timeout specifies the number of milliseconds that a connection is in the TIME-WAIT state before closing. The maximum value is 65535 milliseconds (65.535 seconds). The default is 2000 milliseconds (2 seconds). A value of 0 implies an indefinite timeout, so a connection will not be deleted for being in the TIME-WAIT state.

Prototype

 set_time_wait_timeout(
    in String [] profile_names,
    in LocalLB__ProfileULong [] values
);

Parameters

Parameter Type Description
profile_names String [] The names of the Traffic Acceleration profiles.
values ProfileULong [] The time wait timeouts, in milliseconds, for the specified profiles.

Return Type

Type Description
void  

Exceptions

Exception Description
Common::AccessDenied Raised if the client credentials are not valid.
Common::InvalidArgument Raised if one of the arguments is invalid.
Common::OperationFailed Raised if an operation error occurs.

See Also

Warning

The links to the sample code below are remnants of the old DevCentral wiki and will result in a 404 error. For best results, please copy the link text and search the codeshare directly on DevCentral.

Sample Code


The BIG-IP API Reference documentation contains community-contributed content. F5 does not monitor or control community code contributions. We make no guarantees or warranties regarding the available code, and it may contain errors, defects, bugs, inaccuracies, or security vulnerabilities. Your access to and use of any code available in the BIG-IP API reference guides is solely at your own risk.