sys integrity status-check
sys integrity status-check(1) BIG-IP TMSH Manual sys integrity status-check(1)
NAME
status-check - Checks and verifies the integrity of the BIG-IP BIOS and kernel using the tpm-status utility.
MODULE
sys integrity
SYNTAX
Run a check on the system's integrity status in the sys integrity module by using the syntax below.
RUN
run status-check
options:
-h Print help for the tpm-status command.
-c Attempt to continue after reaching an error.
-o Output the PCR measurements to a given file after measurement. The file will be overwritten if pre-existing.
-a Append the PCR measurements to a given file after measurement.
-v [0|1|2|3] Modify the verbosity of the tpm-status utility from 0 (not verbose) to 3 (very very verbose). Default value: 0.
-q Generates a file containing system information needed for Remote Attestation. File is located at /var/log/pcrs.json.
Note: Options -o and -a are mutually exclusive. Files may only be written to areas allowed by tmsh.
DESCRIPTION
You can use the status-check command to check the system's integrity status.
EXAMPLES
run status-check
Runs the tpm-status utility and returns the integrity status. It shall be one of VALID, INVALID, UNAVAILABLE,
or PENDING.
run status-check -v 3
Runs the tpm-status utility with very very verbose output then returns the integrity status.
SEE ALSO
run, tmsh
COPYRIGHT
No part of this program may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose
other than the purchaser's personal use, without the express written permission of F5 Networks, Inc.
F5 Networks and BIG-IP (c) Copyright 2009-2013, 2017. All rights reserved.
BIG-IP 2018-05-07 sys integrity status-check(1)